serial: samsung: enable clock before accessing interrupt mask resister
Ensure that the uart clock is enabled prior to writing to the interrupt mask register in s3c24xx_serial_resume_noirq function. Without enabing the uart clock, the uart register cannot be accessed. Signed-off-by: Youngmin Nam <youngmin.nam@samsung.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>