Commit a9814d7f authored by Bodong Wang's avatar Bodong Wang Committed by Saeed Mahameed

net/mlx5: E-Switch, Remove redundant warning when QoS enable failed

esw_vport_enable_qos can return error in cases below:
1. QoS is already enabled. Warnning is useless in this case.
2. Create scheduling element cmd failed. There is already a warning.

Remove the redundant warnning if esw_vport_enable_qos returns err.
Signed-off-by: default avatarBodong Wang <bodong@mellanox.com>
Reviewed-by: default avatarParav Pandit <parav@mellanox.com>
Signed-off-by: default avatarSaeed Mahameed <saeedm@mellanox.com>
parent 14c844cb
......@@ -1801,9 +1801,7 @@ static int esw_enable_vport(struct mlx5_eswitch *esw, struct mlx5_vport *vport,
goto done;
/* Attach vport to the eswitch rate limiter */
if (esw_vport_enable_qos(esw, vport, vport->info.max_rate,
vport->qos.bw_share))
esw_warn(esw->dev, "Failed to attach vport %d to eswitch rate limiter", vport_num);
esw_vport_enable_qos(esw, vport, vport->info.max_rate, vport->qos.bw_share);
/* Sync with current vport context */
vport->enabled_events = enabled_events;
......