net: axienet: Enable more clocks
This driver was only enabling the first clock on the device, regardless of its name. However, this controller logic can have multiple clocks which should all be enabled. Add support for enabling additional clocks. The clock names used are matching those used in the Xilinx version of this driver as well as the Xilinx device tree generator, except for mgt_clk which is not present there. For backward compatibility, if no named clocks are present, the first clock present is used for determining the MDIO bus clock divider. Reviewed-by: Radhey Shyam Pandey <radhey.shyam.pandey@xilinx.com> Signed-off-by: Robert Hancock <robert.hancock@calian.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>