Commit b4210eab authored by Yazen Ghannam's avatar Yazen Ghannam Committed by Borislav Petkov

EDAC/amd64: Set proper family type for Family 19h Models 20h-2Fh

AMD Family 19h Models 20h-2Fh use the same PCI IDs as Family 17h Models
70h-7Fh. The same family ops and number of channels also apply.

Use the Family17h Model 70h family_type and ops for Family 19h Models
20h-2Fh. Update the controller name to match the system.
Signed-off-by: default avatarYazen Ghannam <yazen.ghannam@amd.com>
Signed-off-by: default avatarBorislav Petkov <bp@suse.de>
Link: https://lkml.kernel.org/r/20201009171803.3214354-1-Yazen.Ghannam@amd.com
parent e6bbde8b
......@@ -3385,6 +3385,12 @@ static struct amd64_family_type *per_family_init(struct amd64_pvt *pvt)
break;
case 0x19:
if (pvt->model >= 0x20 && pvt->model <= 0x2f) {
fam_type = &family_types[F17_M70H_CPUS];
pvt->ops = &family_types[F17_M70H_CPUS].ops;
fam_type->ctl_name = "F19h_M20h";
break;
}
fam_type = &family_types[F19_CPUS];
pvt->ops = &family_types[F19_CPUS].ops;
family_types[F19_CPUS].ctl_name = "F19h";
......