Commit c05f477c authored by Patrick Rudolph's avatar Patrick Rudolph Committed by Guenter Roeck

hwmon: (pmbus/core) Implement regulator get_status

Add get_status for pmbus_regulator_ops.
Signed-off-by: default avatarPatrick Rudolph <patrick.rudolph@9elements.com>
Signed-off-by: default avatarNaresh Solanki <Naresh.Solanki@9elements.com>
Link: https://lore.kernel.org/r/20221124193642.4081054-1-Naresh.Solanki@9elements.comSigned-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 3ca0f12a
......@@ -2855,6 +2855,49 @@ static int pmbus_regulator_get_error_flags(struct regulator_dev *rdev, unsigned
return 0;
}
static int pmbus_regulator_get_status(struct regulator_dev *rdev)
{
struct device *dev = rdev_get_dev(rdev);
struct i2c_client *client = to_i2c_client(dev->parent);
struct pmbus_data *data = i2c_get_clientdata(client);
u8 page = rdev_get_id(rdev);
int status, ret;
mutex_lock(&data->update_lock);
status = pmbus_get_status(client, page, PMBUS_STATUS_WORD);
if (status < 0) {
ret = status;
goto unlock;
}
if (status & PB_STATUS_OFF) {
ret = REGULATOR_STATUS_OFF;
goto unlock;
}
/* If regulator is ON & reports power good then return ON */
if (!(status & PB_STATUS_POWER_GOOD_N)) {
ret = REGULATOR_STATUS_ON;
goto unlock;
}
ret = pmbus_regulator_get_error_flags(rdev, &status);
if (ret)
goto unlock;
if (status & (REGULATOR_ERROR_UNDER_VOLTAGE | REGULATOR_ERROR_OVER_CURRENT |
REGULATOR_ERROR_REGULATION_OUT | REGULATOR_ERROR_FAIL | REGULATOR_ERROR_OVER_TEMP)) {
ret = REGULATOR_STATUS_ERROR;
goto unlock;
}
ret = REGULATOR_STATUS_UNDEFINED;
unlock:
mutex_unlock(&data->update_lock);
return ret;
}
static int pmbus_regulator_get_low_margin(struct i2c_client *client, int page)
{
struct pmbus_data *data = i2c_get_clientdata(client);
......@@ -2995,6 +3038,7 @@ const struct regulator_ops pmbus_regulator_ops = {
.disable = pmbus_regulator_disable,
.is_enabled = pmbus_regulator_is_enabled,
.get_error_flags = pmbus_regulator_get_error_flags,
.get_status = pmbus_regulator_get_status,
.get_voltage = pmbus_regulator_get_voltage,
.set_voltage = pmbus_regulator_set_voltage,
.list_voltage = pmbus_regulator_list_voltage,
......