power: supply: bq25890: Reduce reported CONSTANT_CHARGE_CURRENT_MAX for low temperatures
Take into account possible current reduction due to low-temperature when reading POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX. As described in the datasheet in cool (0-20° Celcius) conditions the current limit is decreased to 20% or 50% of ICHG field value depended on JEITA_ISET field. Also add NTC_FAULT field value to the debug message in bq25890_get_chip_state(). Changed by Hans de Goede: - Fix reading F_CHG_FAULT instead of F_NTC_FIELD for state->ntc_fault - Only read JEITA_ISET field if necessary - Tweak commit message a bit Signed-off-by: Yauhen Kharuzhy <jekhor@gmail.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Co-developed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Showing
Please register or sign in to comment