firmware: arm_scmi: Check CLOCK_RATE_SET_COMPLETE async response
When CLOCK_RATE_SET command is issued in asynchronous mode the delayed response CLOCK_RATE_SET_COMPLETE comes back once the SCMI platform has effectively operated the requested change: such delayed response carries also the clock ID and the final clock rate that has been set. As an aid to debug issues, check that the clock ID in the delayed response matches the expected one and debug print the rate value. Link: https://lore.kernel.org/r/20220330150551.2573938-8-cristian.marussi@arm.comSigned-off-by: Cristian Marussi <cristian.marussi@arm.com> Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>