Commit c7e37cc6 authored by Hans de Goede's avatar Hans de Goede Committed by Dmitry Torokhov

Input: goodix - try resetting the controller when no config is set

On ACPI systems (irq_pin_access_method == IRQ_PIN_ACCESS_ACPI_*) the driver
does not reset the controller at probe time, because sometimes the system
firmware loads a config and resetting might loose this config.

On the Nanote UMPC-01 device OTOH the config is in flash of the controller,
the controller needs a reset to load this; and the system firmware does not
reset the controller on a cold boot.

To fix the Nanote UMPC-01 touchscreen not working on a cold boot, try
resetting the controller and then re-reading the config when encountering
a config with 0 width/height/max_touch_num value and the controller has
not already been reset by goodix_ts_probe().

This should be safe to do in general because normally we should never
encounter a config with 0 width/height/max_touch_num. Doing this in
general not only avoids the need for a DMI quirk, but also might help
other systems.
Signed-off-by: default avatarHans de Goede <hdegoede@redhat.com>
Reviewed-by: default avatarBastien Nocera <hadess@hadess.net>
Link: https://lore.kernel.org/r/20221025122930.421377-2-hdegoede@redhat.comSigned-off-by: default avatarDmitry Torokhov <dmitry.torokhov@gmail.com>
parent a01aca4b
......@@ -1158,6 +1158,7 @@ static int goodix_configure_dev(struct goodix_ts_data *ts)
input_set_abs_params(ts->input_dev, ABS_MT_WIDTH_MAJOR, 0, 255, 0, 0);
input_set_abs_params(ts->input_dev, ABS_MT_TOUCH_MAJOR, 0, 255, 0, 0);
retry_read_config:
/* Read configuration and apply touchscreen parameters */
goodix_read_config(ts);
......@@ -1165,6 +1166,16 @@ static int goodix_configure_dev(struct goodix_ts_data *ts)
touchscreen_parse_properties(ts->input_dev, true, &ts->prop);
if (!ts->prop.max_x || !ts->prop.max_y || !ts->max_touch_num) {
if (!ts->reset_controller_at_probe &&
ts->irq_pin_access_method != IRQ_PIN_ACCESS_NONE) {
dev_info(&ts->client->dev, "Config not set, resetting controller\n");
/* Retry after a controller reset */
ts->reset_controller_at_probe = true;
error = goodix_reset(ts);
if (error)
return error;
goto retry_read_config;
}
dev_err(&ts->client->dev,
"Invalid config (%d, %d, %d), using defaults\n",
ts->prop.max_x, ts->prop.max_y, ts->max_touch_num);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment