arm64: dts: ti: k3-j7200: Add general purpose timers
There are 20 general purpose timers on j721e that can be used for things like PWM using pwm-omap-dmtimer driver. There are also additional ten timers in the MCU domain which are meant for MCU firmware usage and hence marked reserved by default. The odd numbered timers have the option of being cascaded to even timers to create a 64 bit non-atomic counter which is racy in simple usage, hence the clock muxes are explicitly setup to individual 32 bit counters driven off system crystal (HFOSC) as default. Signed-off-by: Udit Kumar <u-kumar1@ti.com> Reviewed-by: Tony Lindgren <tony@atomide.com> Reviewed-by: Nishanth Menon <nm@ti.com> Link: https://lore.kernel.org/r/20230611111140.3189111-2-u-kumar1@ti.comSigned-off-by: Vignesh Raghavendra <vigneshr@ti.com>