pwm: jz4740: Use clocks from TCU driver
The ingenic-timer "TCU" driver provides us with clocks, that can be (un)gated, reparented or reclocked from devicetree, instead of having these settings hardcoded in this driver. The new code now uses a clk pointer per PWM (instead of a clk per pwm-chip before). So the pointer is stored in per-pwm data now. The calls to arch-specific timer code is replaced with standard clock API calls to start and stop each channel's clock. While this driver is devicetree-compatible, it is never (as of now) probed from devicetree, so this change does not introduce a ABI problem with current devicetree files. Signed-off-by: Paul Cercueil <paul@crapouillou.net> Tested-by: Mathieu Malaterre <malat@debian.org> Tested-by: Artur Rojek <contact@artur-rojek.eu> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>