hwmon: (tmp102) Fix first temperature reading
Commit 3d8f7a89 ("hwmon: (tmp102) Improve handling of initial read delay") reduced the initial temperature read delay and made it dependent on the chip's shutdown mode. If the chip was not in shutdown mode at probe, the read delay no longer applies. This ignores the fact that the chip initialization changes the temperature sensor resolution, and that the temperature register values change when the resolution is changed. As a result, the reported temperature is twice as high as the real temperature until the first temperature conversion after the configuration change is complete. This can result in unexpected behavior and, worst case, in a system shutdown. To fix the problem, let's just always wait for a conversion to complete before reporting a temperature. Fixes: 3d8f7a89 ("hwmon: (tmp102) Improve handling of initial read delay") Link: https://bugzilla.kernel.org/show_bug.cgi?id=197167Reported-by: Ralf Goebel <ralf.goebel@imago-technologies.com> Cc: Ralf Goebel <ralf.goebel@imago-technologies.com> Reviewed-by: Jean Delvare <jdelvare@suse.de> Signed-off-by: Guenter Roeck <linux@roeck-us.net>