Commit d2334a91 authored by Ulf Hansson's avatar Ulf Hansson Committed by Rob Herring

dt-bindings: arm: Fixup the DT bindings for hierarchical PSCI states

The hierarchical topology with power-domain should be described through
child nodes, rather than as currently described in the PSCI root node. Fix
this by adding a patternProperties with a corresponding reference to the
power-domain DT binding.

Additionally, update the example to conform to the new pattern, but also to
the adjusted domain-idle-state DT binding.

Fixes: a3f048b5 ("dt: psci: Update DT bindings to support hierarchical PSCI states")
Signed-off-by: default avatarUlf Hansson <ulf.hansson@linaro.org>
[robh: Add missing allOf, tweak power-domain node name]
Signed-off-by: default avatarRob Herring <robh@kernel.org>
parent 14ee09a0
......@@ -102,11 +102,12 @@ properties:
[1] Kernel documentation - ARM idle states bindings
Documentation/devicetree/bindings/arm/idle-states.yaml
"#power-domain-cells":
description:
The number of cells in a PM domain specifier as per binding in [3].
Must be 0 as to represent a single PM domain.
patternProperties:
"^power-domain-":
allOf:
- $ref: "../power/power-domain.yaml#"
type: object
description: |
ARM systems can have multiple cores, sometimes in an hierarchical
arrangement. This often, but not always, maps directly to the processor
power topology of the system. Individual nodes in a topology have their
......@@ -122,15 +123,9 @@ properties:
helps to implement support for OSI mode and OS implementations may choose
to mandate it.
[3] Documentation/devicetree/bindings/power/power_domain.txt
[3] Documentation/devicetree/bindings/power/power-domain.yaml
[4] Documentation/devicetree/bindings/power/domain-idle-state.yaml
power-domains:
$ref: '/schemas/types.yaml#/definitions/phandle-array'
description:
List of phandles and PM domain specifiers, as defined by bindings of the
PM domain provider.
required:
- compatible
- method
......@@ -224,6 +219,9 @@ examples:
exit-latency-us = <10>;
min-residency-us = <100>;
};
};
domain-idle-states {
CLUSTER_RET: cluster-retention {
compatible = "domain-idle-state";
......@@ -247,19 +245,19 @@ examples:
compatible = "arm,psci-1.0";
method = "smc";
CPU_PD0: cpu-pd0 {
CPU_PD0: power-domain-cpu0 {
#power-domain-cells = <0>;
domain-idle-states = <&CPU_PWRDN>;
power-domains = <&CLUSTER_PD>;
};
CPU_PD1: cpu-pd1 {
CPU_PD1: power-domain-cpu1 {
#power-domain-cells = <0>;
domain-idle-states = <&CPU_PWRDN>;
power-domains = <&CLUSTER_PD>;
};
CLUSTER_PD: cluster-pd {
CLUSTER_PD: power-domain-cluster {
#power-domain-cells = <0>;
domain-idle-states = <&CLUSTER_RET>, <&CLUSTER_PWRDN>;
};
......