Commit d4e9e7b6 authored by Sebastian Krzyszkowiak's avatar Sebastian Krzyszkowiak Committed by Sebastian Reichel

power: supply: bq25890: Use the correct range for IILIM register

I've checked bq25890, bq25892, bq25895 and bq25896 datasheets and
they all define IILIM to be between 100mA-3.25A with 50mA steps.

Fixes: 478efc79 ("power: bq25890: implement INPUT_CURRENT_LIMIT property")
Signed-off-by: default avatarSebastian Krzyszkowiak <sebastian.krzyszkowiak@puri.sm>
Reviewed-by: default avatarMichał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent aa4302c4
......@@ -299,7 +299,7 @@ static const union {
/* TODO: BQ25896 has max ICHG 3008 mA */
[TBL_ICHG] = { .rt = {0, 5056000, 64000} }, /* uA */
[TBL_ITERM] = { .rt = {64000, 1024000, 64000} }, /* uA */
[TBL_IILIM] = { .rt = {50000, 3200000, 50000} }, /* uA */
[TBL_IILIM] = { .rt = {100000, 3250000, 50000} }, /* uA */
[TBL_VREG] = { .rt = {3840000, 4608000, 16000} }, /* uV */
[TBL_BOOSTV] = { .rt = {4550000, 5510000, 64000} }, /* uV */
[TBL_SYSVMIN] = { .rt = {3000000, 3700000, 100000} }, /* uV */
......