firewire: ohci: do not clear PHY interrupt status inadvertently

The interrupt status bits in PHY register 5 are cleared by writing a one
bit.  To avoid clearing them unadvertently, do not write them back when
they were read as set, but only when they have been explicitly requested
to be set.
Signed-off-by: default avatarClemens Ladisch <clemens@ladisch.de>
Signed-off-by: default avatarStefan Richter <stefanr@s5r6.in-berlin.de>
parent 4a96b4fc
......@@ -28,6 +28,7 @@ struct fw_packet;
#define PHY_CONTENDER 0x40
#define PHY_BUS_RESET 0x40
#define PHY_BUS_SHORT_RESET 0x40
#define PHY_INT_STATUS_BITS 0x3c
#define BANDWIDTH_AVAILABLE_INITIAL 4915
#define BROADCAST_CHANNEL_INITIAL (1 << 31 | 31)
......
......@@ -490,6 +490,13 @@ static int ohci_update_phy_reg(struct fw_card *card, int addr,
if (err < 0)
return err;
/*
* The interrupt status bits are cleared by writing a one bit.
* Avoid clearing them unless explicitly requested in set_bits.
*/
if (addr == 5)
clear_bits |= PHY_INT_STATUS_BITS;
old = (old & ~clear_bits) | set_bits;
reg_write(ohci, OHCI1394_PhyControl,
OHCI1394_PhyControl_Write(addr, old));
......