Commit f47c1b02 authored by Viresh Kumar's avatar Viresh Kumar Committed by Greg Kroah-Hartman

greybus: operation: Drop alignment attribute from operation message header

The buffers allocated for message header is already 64 bit aligned and
we have explicit pad bytes in the header structure, to 64 bit align the
operation specific data.

And so there is no need to add the aligned attribute to the operation
message header. Drop it.
Suggested-by: default avatarJohan Hovold <johan@hovoldconsulting.com>
Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: default avatarAlex Elder <elder@linaro.org>
Reviewed-by: default avatarJohan Hovold <johan@hovoldconsulting.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@google.com>
parent a9649356
......@@ -62,7 +62,7 @@ enum gb_operation_result {
*
* The wire format for all numeric fields in the header is little
* endian. Any operation-specific data begins immediately after the
* header, and is 64-bit aligned.
* header.
*/
struct gb_operation_msg_hdr {
__le16 size; /* Size in bytes of header + payload */
......@@ -70,7 +70,7 @@ struct gb_operation_msg_hdr {
__u8 type; /* E.g GB_I2C_TYPE_* or GB_GPIO_TYPE_* */
__u8 result; /* Result of request (in responses only) */
__u8 pad[2]; /* must be zero (ignore when read) */
} __aligned(sizeof(u64));
};
#define GB_OPERATION_MESSAGE_SIZE_MIN sizeof(struct gb_operation_msg_hdr)
#define GB_OPERATION_MESSAGE_SIZE_MAX U16_MAX
......