thermal: cpu_cooling: Actually trace CPU load in thermal_power_cpu_get_power

BugLink: https://bugs.launchpad.net/bugs/1864773

[ Upstream commit bf45ac18 ]

The CPU load values passed to the thermal_power_cpu_get_power
tracepoint are zero for all CPUs, unless, unless the
thermal_power_cpu_limit tracepoint is enabled too:

  irq/41-rockchip-98    [000] ....   290.972410: thermal_power_cpu_get_power:
  cpus=0000000f freq=1800000 load={{0x0,0x0,0x0,0x0}} dynamic_power=4815

vs

  irq/41-rockchip-96    [000] ....    95.773585: thermal_power_cpu_get_power:
  cpus=0000000f freq=1800000 load={{0x56,0x64,0x64,0x5e}} dynamic_power=4959
  irq/41-rockchip-96    [000] ....    95.773596: thermal_power_cpu_limit:
  cpus=0000000f freq=408000 cdev_state=10 power=416

There seems to be no good reason for omitting the CPU load information
depending on another tracepoint. My guess is that the intention was to
check whether thermal_power_cpu_get_power is (still) enabled, however
'load_cpu != NULL' already indicates that it was at least enabled when
cpufreq_get_requested_power() was entered, there seems little gain
from omitting the assignment if the tracepoint was just disabled, so
just remove the check.

Fixes: 6828a471 ("thermal: add trace events to the power allocator governor")
Signed-off-by: default avatarMatthias Kaehlcke <mka@chromium.org>
Reviewed-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: default avatarJavi Merino <javi.merino@kernel.org>
Acked-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarEduardo Valentin <edubezval@gmail.com>
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>
Signed-off-by: default avatarKhalid Elmously <khalid.elmously@canonical.com>
Signed-off-by: default avatarKleber Sacilotto de Souza <kleber.souza@canonical.com>
parent 176b0896
...@@ -607,7 +607,7 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, ...@@ -607,7 +607,7 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
load = 0; load = 0;
total_load += load; total_load += load;
if (trace_thermal_power_cpu_limit_enabled() && load_cpu) if (load_cpu)
load_cpu[i] = load; load_cpu[i] = load;
i++; i++;
......