Merge branch 'mlxsw-Expose-critical-and-emergency-module-alarms'
Ido Schimmel says:
====================
mlxsw: Expose critical and emergency module alarms
Amit says:
Extend hwmon interface with critical and emergency module alarms.
In case that current module temperature is higher than emergency
threshold, EMERGENCY alarm will be reported in sensors utility:
$ sensors
...
front panel 025: +55.0°C (crit = +35.0°C, emerg = +40.0°C) ALARM(EMERGENCY)
In case that current module temperature is higher than critical
threshold, CRIT alarm will be reported in sensors utility:
$ sensors
...
front panel 025: +54.0°C (crit = +35.0°C, emerg = +80.0°C) ALARM(CRIT)
Patch set overview:
Patches #1-#2 make several changes to make the code easier to change.
Patch #3 extends the hwmon interface with the new module alarms.
====================
Signed-off-by: David S. Miller <davem@davemloft.net>