- 24 Jan, 2018 30 commits
-
-
Dmitry Safonov authored
o Change process name in ps output: looks like, these days the process is named kpktgend_<cpu>, rather than pktgen/<cpu>. o Use pg_ctrl for start/stop as it can work well with pgset without changes to $(PGDEV) variable. o Clarify a bit needed $(PGDEV) definition for sample scripts and that one needs to `source functions.sh`. o Document how-to unset a behaviour flag, note about history expansion. o Fix pgset spi parameter value. Cc: Jonathan Corbet <corbet@lwn.net> Cc: linux-doc@vger.kernel.org Signed-off-by: Dmitry Safonov <dima@arista.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
David S. Miller authored
Rahul Lakkireddy says: ==================== cxgb4: fix build error Patch 1 fixes build error with compiling cudbg_zlib.c when CONFIG_ZLIB_DEFLATE macro is not defined. Patch 2 fixes following sparse warning: "Using plain integer as NULL pointer" ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
-
Rahul Lakkireddy authored
memset variables to 0 to fix sparse warnings: drivers/net/ethernet/chelsio/cxgb4/cxgb4_cudbg.c:409:42: sparse: Using plain integer as NULL pointer drivers/net/ethernet/chelsio/cxgb4/cudbg_zlib.c:43:47: sparse: Using plain integer as NULL pointer Fixes: ad75b7d3 ("cxgb4: implement ethtool dump data operations") Fixes: 91c1953d ("cxgb4: use zlib deflate to compress firmware dump") Signed-off-by: Rahul Lakkireddy <rahul.lakkireddy@chelsio.com> Signed-off-by: Ganesh Goudar <ganeshgr@chelsio.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Rahul Lakkireddy authored
Fixes: drivers/net/ethernet/chelsio/cxgb4/cudbg_zlib.c:39:5: error: redefinition of 'cudbg_compress_buff' int cudbg_compress_buff(struct cudbg_init *pdbg_init, ^~~~~~~~~~~~~~~~~~~ In file included from drivers/net/ethernet/chelsio/cxgb4/cudbg_zlib.c:23:0: drivers/net/ethernet/chelsio/cxgb4/cudbg_zlib.h:45:19: note: previous definition of 'cudbg_compress_buff' was here static inline int cudbg_compress_buff(struct cudbg_init *pdbg_init, ^~~~~~~~~~~~~~~~~~~ Fixes: 91c1953d ("cxgb4: use zlib deflate to compress firmware dump") Signed-off-by: Rahul Lakkireddy <rahul.lakkireddy@chelsio.com> Signed-off-by: Ganesh Goudar <ganeshgr@chelsio.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
David S. Miller authored
Ursula Braun says: ==================== net/smc: socket closing improvements while the first 2 patches are just small cleanups, the remaing patches affect socket closing. ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ursula Braun authored
If the peer sends a shutdown WRITE, this should not affect sending in general, and waiting for send buffer space in particular. Stop waiting of the local socket for send buffer space only, if peer signals closing, but not if peer signals just shutdown WRITE. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ursula Braun authored
When a socket is closed or shutdown, smc waits for data being transmitted in certain states. If the state changes during this wait, the close switch depending on state should be reentered. In addition, state change is avoided if sending of close or shutdown fails. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ursula Braun authored
Work requests are needed for every ib_post_send(), among them the ib_post_send() to signal closing. If an smc socket program is cancelled, the smc connections should be cleaned up, and require sending of closing signals to the peer. This may fail, if a wait for a free work request is needed, but is cancelled immediately due to the cancel interrupt. To guarantee notification of the peer, the wait for a work request is changed to uninterruptible. And the area to receive work request completion info with ib_poll_cq() is cleared first. And _tx_ variable names are used in the _tx_routines for the demultiplexing common type in the header. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ursula Braun authored
There is no need to wait for confirmation of pending tx requests for a closing connection, since pending tx slots are dismissed when finishing a connection. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ursula Braun authored
Cleanup to avoid duplicate code in smc_clcsock_accept(). No functional change. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ursula Braun authored
Cleanup to consistently exploit the local struct sock definitions. No functional change. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Ganesh Goudar authored
implement ndo_set_vf_vlan for mgmt netdevice to configure the PCIe VF. Original work by: Casey Leedom <leedom@chelsio.com> Signed-off-by: Ganesh Goudar <ganeshgr@chelsio.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
David S. Miller authored
Jakub Kicinski says: ==================== bpf and netdevsim test updates A number of test improvements (delayed by merges). Quentin provides patches for checking printing to the verifier log from the drivers and validating extack messages are propagated. There is also a test for replacing TC filters to avoid adding back the bug Daniel recently fixed in net and stable. ==================== Acked-by: Daniel Borkmann <daniel@iogearbox.net> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Jakub Kicinski authored
Daniel discovered recently I broke TC filter replace (and fixed it in commit ad9294db ("bpf: fix cls_bpf on filter replace")). Add a test to make sure it never happens again. Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Quentin Monnet authored
Make netdevsim print a message to the BPF verifier log buffer when a program is offloaded. Then use this message in hardware offload selftests to make sure that using this buffer actually prints the message to the console for eBPF hardware offload. The message is appended after the last instruction is processed with the verifying function from netdevsim. Output looks like the following: $ tc filter add dev foo ingress bpf obj sample_ret0.o \ sec .text verbose skip_sw Prog section '.text' loaded (5)! - Type: 3 - Instructions: 2 (0 over limit) - License: Verifier analysis: 0: (b7) r0 = 0 1: (95) exit [netdevsim] Hello from netdevsim! processed 2 insns, stack depth 0 "verbose" flag is required to see it in the console since netdevsim does not throw an error after printing the message. Signed-off-by: Quentin Monnet <quentin.monnet@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Jakub Kicinski authored
We should not compile netdevsim/bpf.c if BPF syscall is not enabled. Otherwise bpf core would have to provide wrappers for all functions offload drivers may call, even though system will never see a BPF object. Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Reviewed-by: Quentin Monnet <quentin.monnet@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Quentin Monnet authored
Add checks to test that netlink extack messages are correctly displayed in some expected error cases for eBPF offload to netdevsim with TC and XDP. iproute2 may be built without libmnl support, in which case the extack messages will not be reported. Try to detect this condition, and when enountered print a mild warning to the user and skip the extack validation. Signed-off-by: Quentin Monnet <quentin.monnet@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Quentin Monnet authored
Use the recently added extack support for TC eBPF filters in netdevsim. Signed-off-by: Quentin Monnet <quentin.monnet@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
git://git.kernel.org/pub/scm/linux/kernel/git/jkirsher/next-queueDavid S. Miller authored
Jeff Kirsher says: ==================== 40GbE Intel Wired LAN Driver Updates 2018-01-23 This series contains updates to i40e and i40evf only. Pawel enables FlatNVM support on x722 devices by allowing nvmupdate tool to configure the preservation flags in the AdminQ command. Mitch fixes a potential divide by zero error when DCB is enabled and the firmware fails to configure the VSI, so check for this state. Fixed a bug where the driver could fail to adhere to ETS bandwidth allocations if 8 traffic classes were configured on the switch. Sudheer fixes a potential deadlock by avoiding to call flush_schedule_work() in i40evf_remove(), since cancel_work_sync() and cancel_delayed_work_sync() already cleans up necessary work items. Fixed an issue with the problematic detection and recovery from hung queues in the PF which was causing lost interrupts. This is done by triggering a software interrupt so that interrupts are forced on and if we are already in napi_poll and an interrupt fires, napi_poll will not be rescheduled and the interrupt is lost. Avinash fixes an issue in the VF where is was possible to issue a reset_task while the device is currently being removed. Michal fixes an issue occurring while calling i40e_led_set() with the blink parameter set to true, which was causing the activity LED instead of the link LED to blink for port identification. Shiraz changes the client interface to not call client close/open on netdev down/up events, since this causes a lot of thrash that is not needed. Instead, disable the PE TCP-ENA flag during a netdev down event and re-enable on a netdev up event, since this blocks all TCP traffic to the RDMA protocol engine. Alan fixes an issue which was causing a potential transmit hang by ignoring the PF link up message if the VF state is not yet in the RUNNING state. Amritha fixes the channel VSI recreation during the reset flow to reconfigure the transmit rings and the queue context associated with the channel VSI. ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
-
David S. Miller authored
Davide Caratti says: ==================== net/sched: remove spinlock from 'csum' action Similarly to what has been done earlier with other actions [1][2], this series tries to improve the performance of 'csum' tc action, removing a spinlock in the data path. Patch 1 lets act_csum use per-CPU counters; patch 2 removes spin_{,un}lock_bh() calls from the act() method. test procedure (using pktgen from https://github.com/netoptimizer): # ip link add name eth1 type dummy # ip link set dev eth1 up # tc qdisc add dev eth1 root handle 1: prio # for a in pass drop; do > tc filter del dev eth1 parent 1: pref 10 matchall action csum udp > tc filter add dev eth1 parent 1: pref 10 matchall action csum udp $a > for n in 2 4; do > ./pktgen_bench_xmit_mode_queue_xmit.sh -v -s 64 -t $n -n 1000000 -i eth1 > done > done test results: | | before patch | after patch $a | $n | avg. pps/thread | avg. pps/thread -----+----+-----------------+---------------- pass | 2 | 1671463 ± 4% | 1920789 ± 3% pass | 4 | 648797 ± 1% | 738190 ± 1% drop | 2 | 3212692 ± 2% | 3719811 ± 2% drop | 4 | 1078824 ± 1% | 1328099 ± 1% references: [1] https://www.spinics.net/lists/netdev/msg334760.html [2] https://www.spinics.net/lists/netdev/msg465862.html v3 changes: - use rtnl_dereference() in place of rcu_dereference() in tcf_csum_dump() v2 changes: - add 'drop' test, it produces more contentions - use RCU-protected struct to store 'action' and 'update_flags', to avoid reading the values from subsequent configurations ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
-
Davide Caratti authored
use RCU instead of spin_{,unlock}_bh() to protect concurrent read/write on act_csum configuration, to reduce the effects of contention in the data path when multiple readers are present. Signed-off-by: Davide Caratti <dcaratti@redhat.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Davide Caratti authored
use per-CPU counters, like other TC actions do, instead of maintaining one set of stats across all cores. This allows updating act_csum stats without the need of protecting them using spin_{,un}lock_bh() invocations. Signed-off-by: Davide Caratti <dcaratti@redhat.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Roopa Prabhu authored
It takes 1sec for bond link down notification to hit user-space when all slaves of the bond go down. 1sec is too long for protocol daemons in user-space relying on bond notification to recover (eg: multichassis lag implementations in user-space). Since the link event code already marks team device port link events as urgent, this patch moves the code to cover all lag ports and master. Signed-off-by: Roopa Prabhu <roopa@cumulusnetworks.com> Acked-by: Jiri Pirko <jiri@mellanox.com> Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
git://git.kernel.org/pub/scm/linux/kernel/git/jkirsher/next-queueDavid S. Miller authored
Jeff Kirsher says: ==================== 10GbE Intel Wired LAN Driver Updates 2018-01-23 This series contains updates to ixgbe only. Shannon Nelson provides an implementation of the ipsec hardware offload feature for the ixgbe driver for these devices: x540, x550, 82599. The ixgbe NICs support ipsec offload for 1024 Rx and 1024 Tx Security Associations (SAs), using up to 128 inbound IP addresses, and using the rfc4106(gcm(aes)) encryption. This code does not yet support checksum offload, or TSO in conjunction with the ipsec offload - those will be added in the future. This code shows improvements in both packet throughput and CPU utilization. For example, here are some quicky numbers that show the magnitude of the performance gain on a single run of "iperf -c <dest>" with the ipsec offload on both ends of a point-to-point connection: 9.4 Gbps - normal case 7.6 Gbps - ipsec with offload 343 Mbps - ipsec no offload ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
-
David S. Miller authored
Sebastian Reichel says: ==================== GEHC Bx50 Switch Support This adds support for the internal switch found in GE Healthcare B450v3, B650v3 and B850v3. All devices use a GPIO bitbanged MDIO bus to communicate with the switch and a PCIe based network card for exchanging network data. The cpu network data link requires, that the switch's internal phy interface is enabled, so support for that is added by the first patch in this series. The patch series is based on v4.15-rc8. Changes since PATCHv4: * Introduce dsa_port_link_(un)register_of and mark the fixed variant static. * Update patch description to describe the phy<->phy connection from i210 to the Marvell switch Changes since PATCHv3: * Enable the phy in dsa_port_setup() instead of abusing the fixed link setup function Changes since PATCHv2: * Add phy nodes to switch in bx50.dtsi and reference them from switch ports * Enable cpu-port's phy based on 'phy-handle' instead of 'phy-mode' Changes since PATCHv1: * Use 'marvell,mv88e6085' instead of introducing compatible string for mv88e6240. * Fix indention of DT nodes * Only enable 'cpu' phy, if explicitly set to "internal". ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
-
Sebastian Reichel authored
This adds support for the Marvell switch and names the network ports according to the labels, that can be found next to the connectors. The switch is connected to the host system using a PCI based network card. The PCI bus configuration has been written using the following information: root@b450v3# lspci -tv -[0000:00]---00.0-[01]----00.0 Intel Corporation I210 Gigabit Network Connection root@b450v3# lspci -nn 00:00.0 PCI bridge [0604]: Synopsys, Inc. Device [16c3:abcd] (rev 01) 01:00.0 Ethernet controller [0200]: Intel Corporation I210 Gigabit Network Connection [8086:1533] (rev 03) Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Sebastian Reichel authored
This adds support for the Marvell switch and names the network ports according to the labels, that can be found next to the connectors. The switch is connected to the host system using a PCI based network card. The PCI bus configuration has been written using the following information: root@b650v3# lspci -tv -[0000:00]---00.0-[01]----00.0 Intel Corporation I210 Gigabit Network Connection root@b650v3# lspci -nn 00:00.0 PCI bridge [0604]: Synopsys, Inc. Device [16c3:abcd] (rev 01) 01:00.0 Ethernet controller [0200]: Intel Corporation I210 Gigabit Network Connection [8086:1533] (rev 03) Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Sebastian Reichel authored
This adds support for the Marvell switch and names the network ports according to the labels, that can be found next to the connectors ("ID", "IX", "ePort 1", "ePort 2"). The switch is connected to the host system using a PCI based network card. The PCI bus configuration has been written using the following information: root@b850v3# lspci -tv -[0000:00]---00.0-[01]----00.0-[02-05]--+-01.0-[03]----00.0 Intel Corporation I210 Gigabit Network Connection +-02.0-[04]----00.0 Intel Corporation I210 Gigabit Network Connection \-03.0-[05]-- root@b850v3# lspci -nn 00:00.0 PCI bridge [0604]: Synopsys, Inc. Device [16c3:abcd] (rev 01) 01:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8605 PCI Express 4-port Gen2 Switch [10b5:8605] (rev ab) 02:01.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8605 PCI Express 4-port Gen2 Switch [10b5:8605] (rev ab) 02:02.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8605 PCI Express 4-port Gen2 Switch [10b5:8605] (rev ab) 02:03.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8605 PCI Express 4-port Gen2 Switch [10b5:8605] (rev ab) 03:00.0 Ethernet controller [0200]: Intel Corporation I210 Gigabit Network Connection [8086:1533] (rev 03) 04:00.0 Ethernet controller [0200]: Intel Corporation I210 Gigabit Network Connection [8086:1533] (rev 03) Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Sebastian Reichel authored
B850v3, B650v3 and B450v3 all have a GPIO bit banged MDIO bus to communicate with a Marvell switch. On all devices the switch is connected to a PCI based network card, which needs to be referenced by DT, so this also adds the common PCI root node. Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
Sebastian Reichel authored
This adds support for enabling the internal PHY for a 'cpu' port. It has been tested on GE B850v3, B650v3 and B450v3, which have a built-in MV88E6240 switch hardwired to a PCIe based network card. On these machines the internal PHY of the i210 network card and the Marvell switch are connected to each other and must be enabled for properly using the switch. While the i210 PHY will be enabled when the network interface is enabled, the switch's port is not exposed as network interface. Additionally the mv88e6xxx driver resets the chip during probe, so the PHY is disabled without this patch. Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-
- 23 Jan, 2018 10 commits
-
-
Amritha Nambiar authored
Fix recreating the channel VSIs during the reset flow to reconfigure the Tx rings and the queue context associated with the channel VSI. Also update the next_base_queue for the VSI while rebuilding the channel VSIs after a reset. Signed-off-by: Amritha Nambiar <amritha.nambiar@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Alan Brady authored
If we receive the link status message from PF with link up before queues are actually enabled, it will trigger a TX hang. This fixes the issue by ignoring a link up message if the VF state is not yet in RUNNING state. Signed-off-by: Alan Brady <alan.brady@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Markus Elfring authored
Omit an extra message for a memory allocation failure in this function. This issue was detected by using the Coccinelle software. Signed-off-by: Markus Elfring <elfring@users.sourceforge.net> Acked-by: Jesse Brandeburg <jesse.brandeburg@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Shiraz Saleem authored
Client close is overloaded to handle both un-registration and netdev down event. On netdev down, i40iw client close is called which unregisters the RDMA dev and this is too destructive since the netdev is still registered. Do not call client close/open on netdev down/up events. Instead disable the PE TCP_ENA flag during a netdev down event. This blocks all TCP traffic to the RDMA Protocol Engine. On netdev up, re-enable the flag. Signed-off-by: Shiraz Saleem <shiraz.saleem@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Mitch Williams authored
Now that i40e_vsi_config_tc() has the pf and hw variable defined, use them, instead of dereferencing vsi->back. Much easier to read. Signed-off-by: Mitch Williams <mitch.a.williams@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Mitch Williams authored
The driver (and the entire netdev layer for that matter) assumes that TC0 will always be present in our DCB configuration. Unfortunately, this isn't always the case. Rather than fail to configure the VSI, let's go ahead and try to make it work, even though DCB will end up being disabled by the kernel. If the driver fails to configure DCB, the driver queries what's valid, then writes that back to the hardware, always forcing TC0. This fixes a bug where the driver could fail to adhere to ETS BW allocations if 8 TCs were configured on the switch. Signed-off-by: Mitch Williams <mitch.a.williams@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Sudheer Mogilappagari authored
In VFs, there is a known issue which can cause writebacks to not occur when interrupts are disabled and there are less than 4 descriptors resulting in TX timeout. Timeout can also occur due to lost interrupt. The current implementation for detecting and recovering from hung queues in the PF is problematic because it actually actively encourages lost interrupts. By triggering a SW interrupt, interrupts are forced on. If we are already in napi_poll and an interrupt fires, napi_poll will not be rescheduled and the interrupt is effectively lost; thereby potentially *causing* hung queues. This patch checks whether packets are being processed between every watchdog cycle and determine potential hung queue and fires triggers SW interrupt only for that particular queue. Signed-off-by: Sudheer Mogilappagari <sudheer.mogilappagari@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Michal Kuchta authored
This fix solves an issue occurring while calling i40e_led_set function from the driver with "blink" parameter set as TRUE. This call resulted in Activity LED blinking instead of Link LED, which may lead to errors in physically identifying the port, since Activity LED may be blinking for different reasons as well. Signed-off-by: Michal Kuchta <michal.kuchta@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Avinash Dayanand authored
When a host disables and enables a PF device, all the associated VFs are removed and added back in. It also generates a PFR which in turn resets all the connected VFs. This behaviour is different from that of Linux guest on Linux host. Hence we end up in a situation where there's a PFR and device removal at the same time. And watchdog doesn't have a clue about this and schedules a reset_task. This patch adds code to send signal to reset_task that the device is currently being removed. Signed-off-by: Avinash Dayanand <avinash.dayanand@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-
Sudheer Mogilappagari authored
flush_schedule_work blocks until completion of all scheduled work items in global work-queue. This can cause deadlock in some cases. i40evf_remove() cleans up necessary work items with cancel_delayed_work_sync and cancel_work_sync. This fix removes flush_schedule_work call inside i40evf_remove(). Signed-off-by: Sudheer Mogilappagari <sudheer.mogilappagari@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-