Commit a8c583f8 authored by Sergey Vojtovich's avatar Sergey Vojtovich

Applying InnoDB snapshot

Detailed revision comments:

r6425 | marko | 2010-01-12 13:47:11 +0200 (Tue, 12 Jan 2010) | 45 lines
branches/zip: Merge revisions 6350:6424 from branches/5.1:

  ------------------------------------------------------------------------
  r6421 | jyang | 2010-01-12 07:59:16 +0200 (Tue, 12 Jan 2010) | 8 lines
  Changed paths:
     M /branches/5.1/row/row0mysql.c

  branches/5.1: Fix bug #49238: Creating/Dropping a temporary table
  while at 1023 transactions will cause assert. Handle possible
  DB_TOO_MANY_CONCURRENT_TRXS when deleting metadata in
  row_drop_table_for_mysql().

  rb://220, approved by Marko
  ------------------------------------------------------------------------
  r6422 | marko | 2010-01-12 11:34:27 +0200 (Tue, 12 Jan 2010) | 3 lines
  Changed paths:
     M /branches/5.1/handler/ha_innodb.cc
     M /branches/5.1/handler/ha_innodb.h

  branches/5.1: Non-functional change:
  Make innobase_get_int_col_max_value() a static function.
  It does not access any fields of class ha_innobase.
  ------------------------------------------------------------------------
  r6424 | marko | 2010-01-12 12:22:19 +0200 (Tue, 12 Jan 2010) | 16 lines
  Changed paths:
     M /branches/5.1/handler/ha_innodb.cc
     M /branches/5.1/handler/ha_innodb.h

  branches/5.1: In innobase_initialize_autoinc(), do not attempt to read
  the maximum auto-increment value from the table if
  innodb_force_recovery is set to at least 4, so that writes are
  disabled. (Bug #46193)

  innobase_get_int_col_max_value(): Move the function definition before
  ha_innobase::innobase_initialize_autoinc(), because that function now
  calls this function.

  ha_innobase::innobase_initialize_autoinc(): Change the return type to
  void.  Do not attempt to read the maximum auto-increment value from
  the table if innodb_force_recovery is set to at least 4.  Issue
  ER_AUTOINC_READ_FAILED to the client when the auto-increment value
  cannot be read.

  rb://144 by Sunny, revised by Marko
  ------------------------------------------------------------------------
parent 2f6a57a9
2010-01-12 The InnoDB Team
* handler/ha_innodb.cc, handler/ha_innodb.h:
Fix Bug #46193 crash when accessing tables after enabling
innodb_force_recovery option
2010-01-12 The InnoDB Team
* row/row0mysql.c:
Fix Bug#49238 Creating/Dropping a temporary table while at 1023
transactions will cause assert.
2009-12-02 The InnoDB Team
* srv/srv0start.c: Display the zlib version number at startup.
* srv/srv0start.c:
Display the zlib version number at startup.
InnoDB compressed tables use zlib, and the implementation depends
on the zlib function compressBound(), whose definition was slightly
changed in zlib version 1.2.3.1 in 2006. MySQL bundles zlib 1.2.3
......
......@@ -3006,59 +3006,150 @@ normalize_table_name(
}
/********************************************************************//**
Get the upper limit of the MySQL integral and floating-point type.
@return maximum allowed value for the field */
static
ulonglong
innobase_get_int_col_max_value(
/*===========================*/
const Field* field) /*!< in: MySQL field */
{
ulonglong max_value = 0;
switch(field->key_type()) {
/* TINY */
case HA_KEYTYPE_BINARY:
max_value = 0xFFULL;
break;
case HA_KEYTYPE_INT8:
max_value = 0x7FULL;
break;
/* SHORT */
case HA_KEYTYPE_USHORT_INT:
max_value = 0xFFFFULL;
break;
case HA_KEYTYPE_SHORT_INT:
max_value = 0x7FFFULL;
break;
/* MEDIUM */
case HA_KEYTYPE_UINT24:
max_value = 0xFFFFFFULL;
break;
case HA_KEYTYPE_INT24:
max_value = 0x7FFFFFULL;
break;
/* LONG */
case HA_KEYTYPE_ULONG_INT:
max_value = 0xFFFFFFFFULL;
break;
case HA_KEYTYPE_LONG_INT:
max_value = 0x7FFFFFFFULL;
break;
/* BIG */
case HA_KEYTYPE_ULONGLONG:
max_value = 0xFFFFFFFFFFFFFFFFULL;
break;
case HA_KEYTYPE_LONGLONG:
max_value = 0x7FFFFFFFFFFFFFFFULL;
break;
case HA_KEYTYPE_FLOAT:
/* We use the maximum as per IEEE754-2008 standard, 2^24 */
max_value = 0x1000000ULL;
break;
case HA_KEYTYPE_DOUBLE:
/* We use the maximum as per IEEE754-2008 standard, 2^53 */
max_value = 0x20000000000000ULL;
break;
default:
ut_error;
}
return(max_value);
}
/************************************************************************
Set the autoinc column max value. This should only be called once from
ha_innobase::open(). Therefore there's no need for a covering lock.
@return DB_SUCCESS or error code */
ha_innobase::open(). Therefore there's no need for a covering lock. */
UNIV_INTERN
ulint
void
ha_innobase::innobase_initialize_autoinc()
/*======================================*/
{
dict_index_t* index;
ulonglong auto_inc;
const char* col_name;
ulint error;
const Field* field = table->found_next_number_field;
col_name = table->found_next_number_field->field_name;
index = innobase_get_index(table->s->next_number_index);
if (field != NULL) {
auto_inc = innobase_get_int_col_max_value(field);
} else {
/* We have no idea what's been passed in to us as the
autoinc column. We set it to the MAX_INT of our table
autoinc type. */
auto_inc = 0xFFFFFFFFFFFFFFFFULL;
/* Execute SELECT MAX(col_name) FROM TABLE; */
error = row_search_max_autoinc(index, col_name, &auto_inc);
ut_print_timestamp(stderr);
fprintf(stderr, " InnoDB: Unable to determine the AUTOINC "
"column name\n");
}
switch (error) {
case DB_SUCCESS:
if (srv_force_recovery >= SRV_FORCE_NO_IBUF_MERGE) {
/* If the recovery level is set so high that writes
are disabled we force the AUTOINC counter to the MAX
value effectively disabling writes to the table.
Secondly, we avoid reading the table in case the read
results in failure due to a corrupted table/index.
We will not return an error to the client, so that the
tables can be dumped with minimal hassle. If an error
were returned in this case, the first attempt to read
the table would fail and subsequent SELECTs would succeed. */
} else if (field == NULL) {
my_error(ER_AUTOINC_READ_FAILED, MYF(0));
} else {
dict_index_t* index;
const char* col_name;
ulonglong read_auto_inc;
ulint err;
/* At the this stage we don't know the increment
or the offset, so use default inrement of 1. */
++auto_inc;
break;
update_thd(ha_thd());
col_name = field->field_name;
index = innobase_get_index(table->s->next_number_index);
case DB_RECORD_NOT_FOUND:
ut_print_timestamp(stderr);
fprintf(stderr, " InnoDB: MySQL and InnoDB data "
"dictionaries are out of sync.\n"
"InnoDB: Unable to find the AUTOINC column %s in the "
"InnoDB table %s.\n"
"InnoDB: We set the next AUTOINC column value to the "
"maximum possible value,\n"
"InnoDB: in effect disabling the AUTOINC next value "
"generation.\n"
"InnoDB: You can either set the next AUTOINC value "
"explicitly using ALTER TABLE\n"
"InnoDB: or fix the data dictionary by recreating "
"the table.\n",
col_name, index->table->name);
/* Execute SELECT MAX(col_name) FROM TABLE; */
err = row_search_max_autoinc(index, col_name, &read_auto_inc);
auto_inc = 0xFFFFFFFFFFFFFFFFULL;
break;
switch (err) {
case DB_SUCCESS:
/* At the this stage we do not know the increment
or the offset, so use a default increment of 1. */
auto_inc = read_auto_inc + 1;
break;
default:
return(error);
case DB_RECORD_NOT_FOUND:
ut_print_timestamp(stderr);
fprintf(stderr, " InnoDB: MySQL and InnoDB data "
"dictionaries are out of sync.\n"
"InnoDB: Unable to find the AUTOINC column "
"%s in the InnoDB table %s.\n"
"InnoDB: We set the next AUTOINC column "
"value to the maximum possible value,\n"
"InnoDB: in effect disabling the AUTOINC "
"next value generation.\n"
"InnoDB: You can either set the next "
"AUTOINC value explicitly using ALTER TABLE\n"
"InnoDB: or fix the data dictionary by "
"recreating the table.\n",
col_name, index->table->name);
my_error(ER_AUTOINC_READ_FAILED, MYF(0));
break;
default:
/* row_search_max_autoinc() should only return
one of DB_SUCCESS or DB_RECORD_NOT_FOUND. */
ut_error;
}
}
dict_table_autoinc_initialize(prebuilt->table, auto_inc);
return(DB_SUCCESS);
}
/*****************************************************************//**
......@@ -3265,8 +3356,6 @@ retry:
/* Only if the table has an AUTOINC column. */
if (prebuilt->table != NULL && table->found_next_number_field != NULL) {
ulint error;
dict_table_autoinc_lock(prebuilt->table);
/* Since a table can already be "open" in InnoDB's internal
......@@ -3275,8 +3364,7 @@ retry:
autoinc value from a previous MySQL open. */
if (dict_table_autoinc_read(prebuilt->table) == 0) {
error = innobase_initialize_autoinc();
ut_a(error == DB_SUCCESS);
innobase_initialize_autoinc();
}
dict_table_autoinc_unlock(prebuilt->table);
......@@ -4092,67 +4180,6 @@ skip_field:
}
}
/********************************************************************//**
Get the upper limit of the MySQL integral and floating-point type. */
UNIV_INTERN
ulonglong
ha_innobase::innobase_get_int_col_max_value(
/*========================================*/
const Field* field)
{
ulonglong max_value = 0;
switch(field->key_type()) {
/* TINY */
case HA_KEYTYPE_BINARY:
max_value = 0xFFULL;
break;
case HA_KEYTYPE_INT8:
max_value = 0x7FULL;
break;
/* SHORT */
case HA_KEYTYPE_USHORT_INT:
max_value = 0xFFFFULL;
break;
case HA_KEYTYPE_SHORT_INT:
max_value = 0x7FFFULL;
break;
/* MEDIUM */
case HA_KEYTYPE_UINT24:
max_value = 0xFFFFFFULL;
break;
case HA_KEYTYPE_INT24:
max_value = 0x7FFFFFULL;
break;
/* LONG */
case HA_KEYTYPE_ULONG_INT:
max_value = 0xFFFFFFFFULL;
break;
case HA_KEYTYPE_LONG_INT:
max_value = 0x7FFFFFFFULL;
break;
/* BIG */
case HA_KEYTYPE_ULONGLONG:
max_value = 0xFFFFFFFFFFFFFFFFULL;
break;
case HA_KEYTYPE_LONGLONG:
max_value = 0x7FFFFFFFFFFFFFFFULL;
break;
case HA_KEYTYPE_FLOAT:
/* We use the maximum as per IEEE754-2008 standard, 2^24 */
max_value = 0x1000000ULL;
break;
case HA_KEYTYPE_DOUBLE:
/* We use the maximum as per IEEE754-2008 standard, 2^53 */
max_value = 0x20000000000000ULL;
break;
default:
ut_error;
}
return(max_value);
}
/********************************************************************//**
This special handling is really to overcome the limitations of MySQL's
binlogging. We need to eliminate the non-determinism that will arise in
......
......@@ -91,9 +91,8 @@ class ha_innobase: public handler
ulint innobase_reset_autoinc(ulonglong auto_inc);
ulint innobase_get_autoinc(ulonglong* value);
ulint innobase_update_autoinc(ulonglong auto_inc);
ulint innobase_initialize_autoinc();
void innobase_initialize_autoinc();
dict_index_t* innobase_get_index(uint keynr);
ulonglong innobase_get_int_col_max_value(const Field* field);
/* Init values for the class: */
public:
......
......@@ -3255,19 +3255,13 @@ check_next_foreign:
"END;\n"
, FALSE, trx);
if (err != DB_SUCCESS) {
ut_a(err == DB_OUT_OF_FILE_SPACE);
err = DB_MUST_GET_MORE_FILE_SPACE;
row_mysql_handle_errors(&err, trx, NULL, NULL);
ut_error;
} else {
switch (err) {
ibool is_temp;
const char* name_or_path;
mem_heap_t* heap;
case DB_SUCCESS:
heap = mem_heap_create(200);
/* Clone the name, in case it has been allocated
......@@ -3333,7 +3327,27 @@ check_next_foreign:
}
mem_heap_free(heap);
break;
case DB_TOO_MANY_CONCURRENT_TRXS:
/* Cannot even find a free slot for the
the undo log. We can directly exit here
and return the DB_TOO_MANY_CONCURRENT_TRXS
error. */
break;
case DB_OUT_OF_FILE_SPACE:
err = DB_MUST_GET_MORE_FILE_SPACE;
row_mysql_handle_errors(&err, trx, NULL, NULL);
/* Fall through to raise error */
default:
/* No other possible error returns */
ut_error;
}
funct_exit:
if (locked_dictionary) {
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment