- 23 Sep, 2009 8 commits
-
-
Alexander Nozdrin authored
when compiled with Sun Studio compiler). The thing is that Sun Studio compiler calls destructor of stack objects when pthread_exit() is called. That triggered an assertion in DBUG_ENTER()/DBUG_RETURN() validation logic (if DBUG_ENTER() is used in the beginning of function, all returns should be replaced by DBUG_RETURN/DBUG_VOID_RETURN macros). A fix is to explicitly use DBUG_LEAVE macro.
-
Satya B authored
-
Satya B authored
value from the index (PRIMARY) With the fix for BUG#46760, we correctly flag the presence of row_type only when it's actually changed and enables the FAST ALTER TABLE which was disabled with the BUG#39200. So the changes made by BUG#46760 makes MySQL data dictionaries to be out of sync but they are handled already by InnoDB with this BUG#44030. The test was originally written to handle this but we requested Innodb to update the test as the data dictionaries were in sync after the fix for BUG#39200. Adjusting the innodb-autoinc testcase as mentioned in the comments.
-
Georgi Kodinov authored
-
Sergey Glukhov authored
the fix is reverted from 5.1, mysql-pe as unnecessary(no valgrind warnings there).
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
- 22 Sep, 2009 2 commits
-
-
Davi Arnaut authored
The "socket" variable is not available on Windows even though the --socket option can be used to specify the pipe name for local connections that use a named pipe. The solution is to ensure that the variable is always defined.
-
Anurag Shekhar authored
-
- 21 Sep, 2009 3 commits
-
-
hery.ramilison@sun.com authored
-
Jonathan Perkin authored
-
Kristofer Pettersson authored
checksum)" The problem was that checksum of GEOMETRY type used memory addresses in the computation, making it un-repeatable thus useless. (This patch is a backport from 6.0 branch)
-
- 18 Sep, 2009 9 commits
-
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
Despite copying the value of the old table's row type we don't always have to mark row type as being specified. Innodb uses this to check if it can do fast ALTER TABLE or not. Fixed by correctly flagging the presence of row_type only when it's actually changed. Added a test case for 39200.
-
Anurag Shekhar authored
-
But there is no Last_IO_Error reported. On the master, if a binary log event is larger than max_allowed_packet, ER_MASTER_FATAL_ERROR_READING_BINLOG and the specific reason of this error is sent to a slave when it requests a dump from the master, thus leading the I/O thread to stop. On a slave, the I/O thread stops when receiving a packet larger than max_allowed_packet. In both cases, however, there was no Last_IO_Error reported. This patch adds code to report the Last_IO_Error and exact reason before stopping the I/O thread and also reports the case the out memory pops up while handling packets from the master.
-
Alexey Kopytov authored
-
Alexey Kopytov authored
Large pages allocator could not allocate more than 4 GB due to incorrect size alignment.
-
- 17 Sep, 2009 6 commits
-
-
Staale Smedseng authored
-
Staale Smedseng authored
with gcc 4.3.2 This is the fifth patch cleaning up more GCC warnings about variables used before initialized using the new macro UNINIT_VAR().
-
Anurag Shekhar authored
"insert into.. select * from" When inserting into a partitioned table using 'insert into <target> select * from <src>', read_buffer_size bytes of memory are allocated for each partition in the target table. This resulted in large memory consumption when the number of partitions are high. This patch introduces a new method which tries to estimate the buffer size required for each partition and limits the maximum buffer size used to maximum of 10 * read_buffer_size, 11 * read_buffer_size in case of monotonic partition functions.
-
Sergey Glukhov authored
additional backport of of bug43138 fix
-
Georgi Kodinov authored
When parsing the service installation parameter in default_service_handling() make sure the value of the optional parameter doesn't overwrite it's name.
-
Satya B authored
1. Fixes BUG#44030 - Error: (1500) Couldn't read the MAX(ID) autoinc value from the index (PRIMARY) 2. Disables the innodb-autoinc test for innodb plugin temporarily. The testcase for this bug has different result file for InnoDB plugin. Should add the testcase to Innodb suite with a different result file. Detailed revision comments: r5243 | sunny | 2009-06-04 03:17:14 +0300 (Thu, 04 Jun 2009) | 14 lines branches/5.1: When the InnoDB and MySQL data dictionaries go out of sync, before the bug fix we would assert on missing autoinc columns. With this fix we allow MySQL to open the table but set the next autoinc value for the column to the MAX value. This effectively disables the next value generation. INSERTs will fail with a generic AUTOINC failure. However, the user should be able to read/dump the table, set the column values explicitly, use ALTER TABLE to set the next autoinc value and/or sync the two data dictionaries to resume normal operations. Fix Bug#44030 Error: (1500) Couldn't read the MAX(ID) autoinc value from the index (PRIMARY) rb://118 r5252 | sunny | 2009-06-04 10:16:24 +0300 (Thu, 04 Jun 2009) | 2 lines branches/5.1: The version of the result file checked in was broken in r5243. r5259 | vasil | 2009-06-05 10:29:16 +0300 (Fri, 05 Jun 2009) | 7 lines branches/5.1: Remove the word "Error" from the printout because the mysqltest suite interprets it as an error and thus the innodb-autoinc test fails. Approved by: Sunny (via IM) r5466 | vasil | 2009-07-02 10:46:45 +0300 (Thu, 02 Jul 2009) | 6 lines branches/5.1: Adjust the failing innodb-autoinc test to conform to the latest behavior of the MySQL code. The idea and the comment in innodb-autoinc.test come from Sunny.
-
- 16 Sep, 2009 2 commits
-
-
Ingo Struewing authored
-
Ingo Struewing authored
-
- 15 Sep, 2009 2 commits
-
-
Kristofer Pettersson authored
-
Kristofer Pettersson authored
-
- 13 Sep, 2009 2 commits
-
-
Luis Soares authored
The test case rpl_do_grant fails sporadically on PB2 with "Access denied for user 'create_rout_db'@'localhost' ...". Inspecting the test case, one may find that if issues a GRANT on the master connection and immediately after it creates two new connections (one to the master and one to the slave) using the credentials set with the GRANT. Unfortunately, there is no synchronization between master and slave after the grant and before the connections are established. This can result in slave not having executed the GRANT by the time the connection is attempted. This patch fixes this by deploying a sync_slave_with_master between the grant and the connections attempt.
-
Luis Soares authored
The test case creates two temporary tables, then closes the connection, waits for it to disconnect, then syncs the slave with the master, checks for remaining opened temporary tables on slave (which should be 0) and finally drops the used database (mysqltest). Unfortunately, sometimes, the test fails with one open table on the slave. This seems to be caused by the fact that waiting for the connection to be closed is not sufficient. The test needs to wait for the DROP event to be logged and only then synchronize the slave with the master and proceed with the check. This is caused by the asynchronous nature of the disconnect wrt binlogging of the DROP temporary table statement. We fix this by deploying a call to wait_for_binlog_event.inc on the test case, which makes execution to wait for the DROP temp tables event before synchronizing master and slave.
-
- 11 Sep, 2009 2 commits
-
-
Mattias Jonsson authored
-
Ramil Kalimullin authored
Problem: LOGGER::general_log_write() relied on valid "thd" parameter passed but had inconsistent "if (thd)" check. Fix: as we always pass a valid "thd" parameter to the method, redundant check removed.
-
- 10 Sep, 2009 4 commits
-
-
Alexander Nozdrin authored
-
Sergey Glukhov authored
-
Sergey Glukhov authored
The problem is that argument buffer can be used as result buffer and it leads to argument value change. The fix is to use 'old buffer' as result buffer only if first argument is not constant item.
-
In RBR, There is an inconsistency between slaves and master. When INSERT statement which includes an auto_increment field is executed, Store engine of master will check the value of the auto_increment field. It will generate a sequence number and then replace the value, if its value is NULL or empty. if the field's value is 0, the store engine will do like encountering the NULL values unless NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE. In contrast, if the field's value is 0, Store engine of slave always generates a new sequence number whether or not NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE. SQL MODE of slave sql thread is always consistency with master's. Another variable is related to this bug. If generateing a sequence number is decided by the values of table->auto_increment_field_not_null and SQL_MODE(if includes MODE_NO_AUTO_VALUE_ON_ZERO) The table->auto_increment_is_not_null is FALSE, which causes this bug to appear. ..
-