Yuval Mintz authored
Each time a flow finishes reads from the classification shadow configuration in the driver, that flow would check for pending commands and pass them to FW if possible. In case there's already a completion pending command, I.e., a ramrod that has been sent to the FW and is yet to be completed while said flow tries to configure the pending command we would get a false error message in logs [and panic if SOE was used for driver compilation] since the command could not have been completed. This prevents said print [and panic]; The pending command will be sent by the time the completion of the current sent command would arrive. Signed-off-by: Yuval Mintz <Yuval.Mintz@qlogic.com> Signed-off-by: Ariel Elior <Ariel.Elior@qlogic.com> Signed-off-by: David S. Miller <davem@davemloft.net>
9d18d270