Ville Syrjälä authored
We're forgetting to mask off all three pipe select bits from the CDCLK_CTL value on icl+ which may lead to the extra bit being left in. That will cause us to consider the current hardware cdclk state as invalid, and we proceed to sanitize it even though the hardware may have active pipes and whatnot. Fix up the mask so we get rid of all three pipe select bits and thus hopefully no longer sanitize cdclk when it's already correctly programmed. Cc: Matt Roper <matthew.d.roper@intel.com> Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=111641 Fixes: 0c1279b5 ("drm/i915: Consolidate {bxt,cnl,icl}_init_cdclk") Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Reviewed-by: Matt Roper <matthew.d.roper@intel.com> Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Link: https://patchwork.freedesktop.org/patch/msgid/20190911133129.27466-2-ville.syrjala@linux.intel.com
0a12e437