Matthias Kaehlcke authored
The current example for a thermal zone isn't very useful as reference since it would result in a hardware shutdown at 145°C, instead of allowing the system to try to shutdown gracefully. Without an ADC channel a maximum of two trip points is useful in practice for this sensor, with temperatures corresponding to the stage 1 and stage 2 'hardware trip points'. A critical trip point at stage 2 may allow the system to shutdown before a hardware shutdown at stage 3 kicks in. It should be noted though that by default the chip performs a 'partial shutdown' when the temperature reaches stage 2, which may prevent an orderly shutdown. The 'partial shutdown' can be disabled by software. Signed-off-by: Matthias Kaehlcke <mka@chromium.org> Reviewed-by: Douglas Anderson <dianders@chromium.org> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
97b27dd3