Hans de Goede authored
When we put the touchscreen controller in low-power mode the irq pin may trigger (float) and if we then try to read a data packet we get the following error in dmesg: [ 478.801017] silead_ts i2c-MSSL1680:00: Data read error -121 This commit disables the irq during suspend/resume fixing this error. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
1943d172