Sara Sharon authored
For a000 devices the INIT and RT images are unified to one image. The changes in the flow are the following: * Driver load only RT firmware - meaning that the nvm access command will be done in the RT image load flow. * A new command (NVM_ACCESS_COMPLETE) now signals to the FW that the driver is done accessing the NVM and FW can proceed with phy calibrations. * Phy DB is no longer sent from INIT FW to be restored by driver for the RT FW - all the phy DB is now internal to the FW. INIT complete will now follow the NVM access command, without phy DB calls before. * Paging command is sent earlier in the flow before NVM access to enable a complete load of FW. * caution must be care when restart is called since we may have not completed init flow even though we are in RT firmware. Signed-off-by: Sara Sharon <sara.sharon@intel.com> Signed-off-by: Luca Coelho <luciano.coelho@intel.com>
1f370650