Tero Kristo authored
commit 62c8c20a upstream. mcp794xx alarm registers must be written in BCD format. However, the alarm programming logic neglected this by adding one to the value after bin2bcd conversion has been already done, writing bad values to month register in case the alarm being set is in October. In this case, the alarm month value becomes 0x0a instead of the expected 0x10. Fix by moving the +1 addition within the bin2bcd call also. Fixes: 1d1945d2 ("drivers/rtc/rtc-ds1307.c: add alarm support for mcp7941x chips") Signed-off-by: Tero Kristo <t-kristo@ti.com> Acked-by: Nishanth Menon <nm@ti.com> Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com> Signed-off-by: Luis Henriques <luis.henriques@canonical.com>
23d8e4e8