Charles Keepax authored
[ Upstream commit 436c2a50 ] commit 3cc81d85 ("asix: Don't reset PHY on if_up for ASIX 88772") causes the ethernet on Arndale to no longer function. This appears to be because the Arndale ethernet requires a full reset before it will function correctly, however simply reverting the above patch causes problems with ethtool settings getting reset. It seems the problem is that the ethernet is not properly reset during bind, and indeed the code in ax88772_bind that resets the device is a very small subset of the actual ax88772_reset function. This patch uses ax88772_reset in place of the existing reset code in ax88772_bind which removes some code duplication and fixes the ethernet on Arndale. It is still possible that the original patch causes some issues with suspend and resume but that seems like a separate issue and I haven't had a chance to test that yet. Signed-off-by: Charles Keepax <ckeepax@opensource.wolfsonmicro.com> Tested-by: Riku Voipio <riku.voipio@linaro.org> Signed-off-by: David S. Miller <davem@davemloft.net> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
37673fd3