Eric Anholt authored
We were setting the wrong flags to enable PTI errors, so we were seeing reads to invalid PTEs show up as write errors. Also, we weren't turning on the interrupts. The AXI IDs we were dumping included the outstanding write number and so they looked basically random. And the VIO_ADDR decoding was based on the MMU VA_WIDTH for the first platform I worked on and was wrong on others. In short, this was a thorough mess from early HW enabling. Tested on V3D 4.1 and 4.2 with intentional L2T, CLE, PTB, and TLB faults. Signed-off-by: Eric Anholt <eric@anholt.net> Link: https://patchwork.freedesktop.org/patch/msgid/20190419001014.23579-4-eric@anholt.netReviewed-by: Paul Kocialkowski <paul.kocialkowski@bootlin.com>
38c2c791