• Olympia Giannou's avatar
    rndis_host: increase sleep time in the query-response loop · 4202c9fd
    Olympia Giannou authored
    Some WinCE devices face connectivity issues via the NDIS interface. They
    fail to register, resulting in -110 timeout errors and failures during the
    probe procedure.
    
    In this kind of WinCE devices, the Windows-side ndis driver needs quite
    more time to be loaded and configured, so that the linux rndis host queries
    to them fail to be responded correctly on time.
    
    More specifically, when INIT is called on the WinCE side - no other
    requests can be served by the Client and this results in a failed QUERY
    afterwards.
    
    The increase of the waiting time on the side of the linux rndis host in
    the command-response loop leaves the INIT process to complete and respond
    to a QUERY, which comes afterwards. The WinCE devices with this special
    "feature" in their ndis driver are satisfied by this fix.
    Signed-off-by: default avatarOlympia Giannou <olympia.giannou@leica-geosystems.com>
    Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
    4202c9fd