Shengzhen Li authored
As interrupt is read in interrupt handler as well as interrupt processing thread, we observed a corner case issue for MSI in which interrupt gets processed twice. This patch moves interrupt reading code for MSI mode from mwifiex_interrupt_status() to mwifiex_pcie_process_int() to avoid the issue. Signed-off-by: Shengzhen Li <szli@marvell.com> Signed-off-by: Amitkumar Karwar <akarwar@marvell.com> Signed-off-by: Kalle Valo <kvalo@codeaurora.org>