• Archit Taneja's avatar
    OMAPDSS: VENC/DISPC: Delay dividing Y resolution for managers connected to VENC · 2aefad49
    Archit Taneja authored
    DSS2 driver uses the timings in manager's private data to check the validity of
    overlay and manager infos written by the user. For VENC interface, we divide the
    Y resolution by half when writing to the DISPC_DIGIT_SIZE register as the
    content is interlaced. However, the height of the manager/display with respect
    to the content shown through VENC still remains the same.
    
    The VENC driver divides the y_res parameter in omap_video_timings by half, and
    then applies the configuration. This leads to manager's private data storing
    the wrong Y resolution. Hence, overlay related checks fail.
    
    Ensure that manager's private data stores the original timings, and the Y
    resolution is halved only when we write to the DISPC register. This is a hack,
    the proper solution would be to pass some sort of interlace parameter which
    makes the call whether we should divide y_res or not.
    Signed-off-by: default avatarArchit Taneja <archit@ti.com>
    Signed-off-by: default avatarTomi Valkeinen <tomi.valkeinen@ti.com>