• Stefan Agner's avatar
    rtc: ds1307: support m41t0 variant · 8566f70c
    Stefan Agner authored
    The m41t0 variant is very similar to the already supported m41t00
    variant, with the notable exception of the oscillator fail bit.
    The data sheet notes:
    
      If the oscillator fail (OF) bit is internally set to a '1,' this
      indicates that the oscillator has either stopped, or was stopped
      for some period of time and can be used to judge the validity of
      the clock and date data.
    
    The bit will get cleared with a regular write of the system time,
    so no changes are needed to clear it.
    Signed-off-by: default avatarStefan Agner <stefan@agner.ch>
    Signed-off-by: default avatarAlexandre Belloni <alexandre.belloni@free-electrons.com>
    8566f70c