• John Stultz's avatar
    rtc: rtc-pl031: Set wakeup flag prior to registering rtcdev · 07783397
    John Stultz authored
    In some recent testing, I noticed the CLOCK_REALTIME_ALARM clockid
    wasn't functioning on my vexpress qemu environment. Looking into it
    I noticed the pl031 rtc driver doesn't set the wakeup flag on the
    device until after registering the device with the RTC subsystem.
    
    This causes the alarmtimer subsystem to not see the pl031 driver
    as a valid backing device, and that resuls in alarm clockids
    getting ENOTSUPP errors.
    
    Thus be sure to set the wakeup flag on the device prior to
    registering the rtcdev so the pl031 rtc driver can be used as
    the backing alarmtimer device.
    
    Cc: Linus Walleij <linus.walleij@linaro.org>
    Cc: Alessandro Zummo <a.zummo@towertech.it>
    Cc: "Jon Medhurst (Tixy)" <tixy@linaro.org>
    Cc: linux-arm-kernel@lists.infradead.org
    Acked-by: default avatarLinus Walleij <linus.walleij@linaro.org>
    Signed-off-by: default avatarJohn Stultz <john.stultz@linaro.org>
    07783397