Andrew Lunn authored
Not all SFPs implement the registers containing sensor limits and alarms. Luckily, there is a bit indicating if they are implemented or not. Add checking for this bit, when deciding if the hwmon attributes should be visible. Fixes: 1323061a ("net: phy: sfp: Add HWMON support for module sensors") Signed-off-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>