-
Subhash Jadavani authored
[ Upstream commit 56d4a186 ] The maximum value PA_SaveConfigTime is 250 (10us) but this is not enough for some vendors. Gear switch from PWM to HS may fail even with this max. PA_SaveConfigTime. Gear switch can be issued by host controller as an error recovery and any software delay will not help on this case so we need to increase PA_SaveConfigTime to >32us as per vendor recommendation. This change adds a quirk to increase the PA_SaveConfigTime parameter. Reviewed-by: Venkat Gopalakrishnan <venkatg@codeaurora.org> Signed-off-by: Subhash Jadavani <subhashj@codeaurora.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com> Signed-off-by: Sasha Levin <alexander.levin@verizon.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
bedc6294