The device could be configured to spit out also the configuration word while reading the AD result value (in the same SPI xfer) - this is called "readback" in the device datasheet. The driver checks if readback is enabled and it eventually adjusts the SPI xfer length and it applies proper shifts to still get the data, discarding the configuration word. The readback option is actually never enabled (the driver disables it), so the said checks do not serve for any purpose. Since enabling the readback option seems not to provide any advantage (the driver entirely sets the configuration word without relying on any default value), just kill the said, unused, code. Signed-off-by: Andrea Merello <andrea.merello@gmail.com> Reviewed-by: Alexandru Ardelean <alexandru.ardelean@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>