Bart Van Assche authored
According to the firmware documentation a status type 0 IOCB can be followed by one or more status continuation type 0 IOCBs. Hence do not complain if the completion function is not called from inside the status type 0 IOCB handler. WARNING: CPU: 10 PID: 425 at drivers/scsi/qla2xxx/qla_isr.c:2784 qla2x00_status_entry.isra.7+0x484/0x17b0 [qla2xxx] CPU: 10 PID: 425 Comm: kworker/10:1 Tainted: G E 5.3.0-rc4-next-20190813-autotest-autotest #1 Workqueue: qla2xxx_wq qla25xx_free_rsp_que [qla2xxx] Call Trace: qla2x00_status_entry.isra.7+0x1484/0x17b0 [qla2xxx] (unreliable) qla24xx_process_response_queue+0x7d8/0xbd0 [qla2xxx] qla25xx_free_rsp_que+0x1a0/0x220 [qla2xxx] process_one_work+0x25c/0x520 worker_thread+0x8c/0x5e0 kthread+0x154/0x1a0 ret_from_kernel_thread+0x5c/0x7c Cc: Himanshu Madhani <hmadhani@marvell.com> Cc: Abdul Haleem <abdhalee@linux.vnet.ibm.com> Reported-by: Abdul Haleem <abdhalee@linux.vnet.ibm.com> Signed-off-by: Bart Van Assche <bvanassche@acm.org> Tested-by: Abdul Haleem <abdhalee@linux.vnet.ibm.com> Reviewed-by: Lee Duncan <lduncan@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
dd93b143