Commit 01ae1070 authored by Sebastian Hesselbarth's avatar Sebastian Hesselbarth Committed by Ulf Hansson

mmc: sdhci-pxav3: Try to get named I/O clock first

With support for more than one clock, we'll need to distinguish between
the clock by name. Change clock probing to first try to get "io" clock
before falling back to unnamed clock.
Signed-off-by: default avatarSebastian Hesselbarth <sebastian.hesselbarth@gmail.com>
Signed-off-by: default avatarUlf Hansson <ulf.hansson@linaro.org>
parent 8c96a7a3
......@@ -309,7 +309,9 @@ static int sdhci_pxav3_probe(struct platform_device *pdev)
pltfm_host = sdhci_priv(host);
pltfm_host->priv = pxa;
pxa->clk_io = devm_clk_get(dev, NULL);
pxa->clk_io = devm_clk_get(dev, "io");
if (IS_ERR(pxa->clk_io))
pxa->clk_io = devm_clk_get(dev, NULL);
if (IS_ERR(pxa->clk_io)) {
dev_err(dev, "failed to get io clock\n");
ret = PTR_ERR(pxa->clk_io);
......