Commit 0ea34b57 authored by Axel Lin's avatar Axel Lin Committed by Mark Brown

regulator: palmas: Fix off-by-one for ramp_delay and register value mapping

Datasheet says:
Time Step (TSTEP) selection, when changing the output voltage, the new value is
reached through successive voltage steps (if not bypassed). The equivalent
programmable slew rate of the output voltage is:

TSTEP[1:0]: 00 Jump (no slope control)
TSTEP[1:0]: 01 10mV/us
TSTEP[1:0]: 10 5mV/us (default)
TSTEP[1:0]: 11 2.5mV/us
Signed-off-by: default avatarAxel Lin <axel.lin@ingics.com>
Acked-by: default avatarLaxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: default avatarMark Brown <broonie@opensource.wolfsonmicro.com>
parent e31089c6
......@@ -447,9 +447,9 @@ static int palmas_smps_set_ramp_delay(struct regulator_dev *rdev,
if (ramp_delay <= 0)
reg = 0;
else if (ramp_delay < 2500)
else if (ramp_delay <= 2500)
reg = 3;
else if (ramp_delay < 5000)
else if (ramp_delay <= 5000)
reg = 2;
else
reg = 1;
......