arm64: don't zero DIT on signal return
Currently valid_user_regs() treats SPSR_ELx.DIT as a RES0 bit, causing it to be zeroed upon exception return, rather than preserved. Thus, code relying on DIT will not function as expected, and may expose an unexpected timing sidechannel. Let's remove DIT from the set of RES0 bits, such that it is preserved. At the same time, the related comment is updated to better describe the situation, and to take into account the most recent documentation of SPSR_ELx, in ARM DDI 0487C.a. Signed-off-by: Mark Rutland <mark.rutland@arm.com> Fixes: 7206dc93 ("arm64: Expose Arm v8.4 features") Cc: Catalin Marinas <catalin.marinas@arm.com> Cc: Suzuki K Poulose <suzuki.poulose@arm.com> Cc: Will Deacon <will.deacon@arm.com> Signed-off-by: Will Deacon <will.deacon@arm.com>