pcf50633: Properly reenable charging when the supply conditions change
If chgmod == BATFULL, setting chgena has no effect. Datasheet says we need to set resume instead but when autoresume is used resume doesn't work. Clear and set chgena instead. This enables a user to force charging by re-plugging USB even when the charger entered Battery Full mode, might be handy before a long trip. Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>