iio: adc: ti-ads1015: avoid getting stale result after runtime resume
commit 73e3e3fc upstream. This driver assumes that the device is operating in the continuous conversion mode which performs the conversion continuously. So this driver doesn't insert a wait time before reading the conversion register if the configuration is not changed from a previous request. This assumption is broken if the device is runtime suspended and entered a power-down state. The forthcoming request causes reading a stale result from the conversion register as the device is runtime resumed just before. Fix it by adding a flag to detect that condition and insert a necessary wait time. Cc: Daniel Baluta <daniel.baluta@gmail.com> Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>