Commit 1f153093 authored by Niklas Söderlund's avatar Niklas Söderlund Committed by Simon Horman

arm64: dts: renesas: r8a7796: decrease temperature hysteresis

To incorporate more tests by the hardware team decrease the hysteresis
value to 1C.
Signed-off-by: default avatarNiklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
parent 02f15e4b
......@@ -2072,12 +2072,12 @@ sensor_thermal1: sensor-thermal1 {
trips {
sensor1_passive: sensor1-passive {
temperature = <95000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "passive";
};
sensor1_crit: sensor1-crit {
temperature = <120000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "critical";
};
};
......@@ -2098,12 +2098,12 @@ sensor_thermal2: sensor-thermal2 {
trips {
sensor2_passive: sensor2-passive {
temperature = <95000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "passive";
};
sensor2_crit: sensor2-crit {
temperature = <120000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "critical";
};
};
......@@ -2124,12 +2124,12 @@ sensor_thermal3: sensor-thermal3 {
trips {
sensor3_passive: sensor3-passive {
temperature = <95000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "passive";
};
sensor3_crit: sensor3-crit {
temperature = <120000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "critical";
};
};
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment