ds2760_battery: handle full_active_uAh == 0 case correctly
In systems where the battery monitor is not part of the battery pack and is hence not bootstrapped with sane values, the full_active_uAh is likely to be zero. Handle that case by defaulting to the rated_capacity information which can be passed to the driver using the new module parameter. Signed-off-by: Daniel Mack <daniel@caiaq.de> Cc: Szabolcs Gyurko <szabolcs.gyurko@tlt.hu> Acked-by: Matt Reimer <mreimer@vpop.net> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Showing
Please register or sign in to comment