net/mlx5: E-Switch, Fix drop counters use before creation

First use of drop counters happens in esw_apply_vport_conf function,
while they are allocated later in the flow. Fix that by moving
esw_vport_create_drop_counters function to be called before the first use.

Fixes: b8a0dbe3 ("net/mlx5e: E-switch, Add steering drop counters")
Signed-off-by: default avatarEugenia Emantayev <eugenia@mellanox.com>
Signed-off-by: default avatarSaeed Mahameed <saeedm@mellanox.com>
parent 96de67a7
......@@ -1529,6 +1529,10 @@ static void esw_enable_vport(struct mlx5_eswitch *esw, int vport_num,
esw_debug(esw->dev, "Enabling VPORT(%d)\n", vport_num);
/* Create steering drop counters for ingress and egress ACLs */
if (vport_num && esw->mode == SRIOV_LEGACY)
esw_vport_create_drop_counters(vport);
/* Restore old vport configuration */
esw_apply_vport_conf(esw, vport);
......@@ -1545,10 +1549,6 @@ static void esw_enable_vport(struct mlx5_eswitch *esw, int vport_num,
if (!vport_num)
vport->info.trusted = true;
/* create steering drop counters for ingress and egress ACLs */
if (vport_num && esw->mode == SRIOV_LEGACY)
esw_vport_create_drop_counters(vport);
esw_vport_change_handle_locked(vport);
esw->enabled_vports++;
......