ARM: OMAP3+: PM: VP: fix integer truncation error
commit 2f34ce81 (OMAP3: PM: Adding voltage driver support.) introduced runtime computation of waittime to handle all potential sys clocks available. In the voltage processor, the SPMSUpdateWait is calculated based on the slew rate and the voltage step (SMPSUpdateWait = slew rate * Voltage Step). After the voltage processor receives the SMPS_Ack signal, the Voltage Controller will wait for SMPSUpdateWait clock cycles for the voltage to settle to the new value. For all practical purposes, the waittime parameter is the OMAP hardware translation of what the slew rate on the PMIC is. As an example, with TPS62361 on OMAP4460, step_size = 10000 slew_rate = 32000 sys_clk_rate = 38400 Our current computation results in the following: = ((step_size / slew_rate) * sys_clk_rate) / 1000 = ((10000 / 32000) * 38400 / 1000 = 0 Fix the same using DIV_ROUND_UP as an extra wait clock cycle is better than lesser clock cycle. For the above example, this translates to: = (10000 * 38400) / (1000 * 32000) = 12 Acked-by: Jon Hunter <jon-hunter@ti.com> [nm@ti.com: slightly better implementation] Signed-off-by: Nishanth Menon <nm@ti.com> Signed-off-by: Yuan Jiangli <jlyuan@motorola.com> Acked-by: Kevin Hilman <khilman@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com>