Commit 33c646e4 authored by Clemens Ladisch's avatar Clemens Ladisch Committed by Jaroslav Kysela

[ALSA] oxygen: fix SPDIF input rates

Fix up SPDIF input sample rates again: 32 kHz and 64 kHz are not
supported.
Signed-off-by: default avatarClemens Ladisch <clemens@ladisch.de>
Signed-off-by: default avatarJaroslav Kysela <perex@perex.cz>
parent 9478bc3b
......@@ -119,6 +119,11 @@ static int oxygen_open(struct snd_pcm_substream *substream,
runtime->private_data = (void *)(uintptr_t)channel;
runtime->hw = *oxygen_hardware[channel];
if (channel == PCM_C) {
runtime->hw.rates &= ~(SNDRV_PCM_RATE_32000 |
SNDRV_PCM_RATE_64000);
runtime->hw.rate_min = 44100;
}
if (chip->model->pcm_hardware_filter)
chip->model->pcm_hardware_filter(channel, &runtime->hw);
err = snd_pcm_hw_constraint_step(runtime, 0,
......
Markdown is supported