Commit 35f4f99c authored by Tony Lindgren's avatar Tony Lindgren Committed by Sebastian Reichel

power: supply: cpcap-charger: Keep trickle charger bits disabled

Android does not seem to set the trickle charger bits, and these
seem to be only used by the bootloader when bringing up a
completely discharged battery. So let's keep the trickle charging
bits disabled and avoid misconfiguring the hardware.

Fixes: 0c9888e3 ("power: supply: cpcap-charger: Add minimal
CPCAP PMIC battery charger")
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.co.uk>
parent 6ffa8ace
......@@ -434,8 +434,7 @@ static void cpcap_usb_detect(struct work_struct *work)
error = cpcap_charger_set_state(ddata,
CPCAP_REG_CRM_VCHRG_4V35,
max_current,
CPCAP_REG_CRM_TR_0A72);
max_current, 0);
if (error)
goto out_err;
} else {
......