Commit 49718b17 authored by Lin Ming's avatar Lin Ming Committed by Len Brown

ACPICA: Added additional parameter validation for LoadTable

Implemented additional parameter validation for the LoadTable
operator. The length of the input strings SignatureString,
OemIdString, and OemTableId are now checked for maximum
lengths.

http://www.acpica.org/bugzilla/show_bug.cgi?id=582Signed-off-by: default avatarLin Ming <ming.m.lin@intel.com>
Signed-off-by: default avatarBob Moore <robert.moore@intel.com>
Signed-off-by: default avatarAlexey Starikovskiy <astarikovskiy@suse.de>
Signed-off-by: default avatarLen Brown <len.brown@intel.com>
parent fe4078af
......@@ -138,6 +138,14 @@ acpi_ex_load_table_op(struct acpi_walk_state *walk_state,
ACPI_FUNCTION_TRACE(ex_load_table_op);
/* Validate lengths for the signature_string, OEMIDString, OEMtable_iD */
if ((operand[0]->string.length > ACPI_NAME_SIZE) ||
(operand[1]->string.length > ACPI_OEM_ID_SIZE) ||
(operand[2]->string.length > ACPI_OEM_TABLE_ID_SIZE)) {
return_ACPI_STATUS(AE_BAD_PARAMETER);
}
/* Find the ACPI table in the RSDT/XSDT */
status = acpi_tb_find_table(operand[0]->string.pointer,
......