power: supply: bq24190_charger: Don't read fault register outside irq_handle_thread()
commit 68abfb80 upstream. Caching the fault register after a single I2C read may not keep an accurate value. Fix by doing two reads in irq_handle_thread() and using the cached value elsewhere. If a safety timer fault later clears itself, we apparently don't get an interrupt (INT), however other interrupts would refresh the register cache. From the data sheet: "When a fault occurs, the charger device sends out INT and keeps the fault state in REG09 until the host reads the fault register. Before the host reads REG09 and all the faults are cleared, the charger device would not send any INT upon new faults. In order to read the current fault status, the host has to read REG09 two times consecutively. The 1st reads fault register status from the last read [1] and the 2nd reads the current fault register status." [1] presumably a typo; should be "last fault" Fixes: d7bf353f ("bq24190_charger: Add support for TI BQ24190 Battery Charger") Signed-off-by: Liam Breck <kernel@networkimprov.net> Acked-by: Mark Greer <mgreer@animalcreek.com> Acked-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Sebastian Reichel <sre@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>